Where It Is Used
Use Cases

Wire and cable manufacturers
ProductionQuality controlProduction engineering

PVC and plastic pipe manufacturers
Production

Medical catheter manufacturers
ProductionQuality controlProduction engineering

Optical fiber manufacturers
ProductionQuality controlProduction engineering
Challenges We Solve
Solution
- Measure outer diameter continuously without stopping the line
- Guarantee outer diameter to the micron and keep defective products from shipping
- Measure transparent tubing, glass, and similar materials
- Measure reliably without interference from sunlight, room lighting, or other ambient light
- Deploy the right gauge on every line, from fine wire to large-diameter products
Features of Takikawa Vision Outer Diameter Gauges
Features
Our own design technology and more than 40 years of experience deliver high-precision measurement, long service life, and flexible customization.

Examples of Use in Production Processes by Industry
Repeatability of 0.1 μm (sub-micron) from our own combination of optical design and analog circuit design.

40 years of field experience and long-term support for each model
A track record built since the 1980s. We can still repair models more than 15 years old.

Flexible solutions for the needs of each line
Measurement range, communication specifications, and mounting are customized to the characteristics of your line.
Why Customers Choose Takikawa Vision
Why Us
Technology specialized in continuous measurement on extrusion lines, combined with the flexibility of a Japanese manufacturer. We support you from cost-effective adoption and customization through to after-sales support.
Cost-effective pricing and
responsive support from Japan
Easier to introduce than overseas products of comparable accuracy, with responsive support from our team in Japan.
Specialized in continuous
measurement on extrusion lines
Unlike general-purpose gauges, specialized in continuous measurement on extrusion lines (wire, cable, and tubing).
Customizable for
every application
In addition to a wide lineup, customization of communication specifications and mounting is part of our standard service.
Suitable for a Wide Range of Applications
Applications
Industries
Wire & Cable
- Installed right after the extruder on extrusion coating lines to monitor outer diameter in real time
- Final outer diameter inspection in the finishing process just before take-up
Medical tubing and catheters
- 100% inspection measurement after extrusion
PVC and plastic pipe
- Outer diameter control of large-diameter products after extrusion
Examples of Use in Production Processes by Industry
Position on a wire and cable production line
- Material feed
- Extrusion
- LDM measurementInline
- Cooling
- Take-up
- Shipping inspection
Position on an optical fiber production line
- Preform
- LDM measurementPreform diameter
- Drawing
- LOD measurementFiber diameter
- Coating
- Take-up
Customization Examples
Custom Projects
We can customize our products for a wide range of cases.
Customization examples for this product are coming soon.
Options
Option
Specifications
Product Specification
Detector
Single-axis detector, standard type (400-scan type)
| Model | LDM-301H | LDM-302H | LDM-303H | LDM-304H | LDM-305H | LDM-306H | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CAD files | ||||||||||||
| Measurement range | 0.02–1 mm | 0.05–5 mm | 0.3–30 mm | 0.5–90 mm | 1–180 mm | 2–300 mm[*1] | ||||||
| Measurement accuracy[*2] | ±1μm | ±1μm | ±2μm | ±5μm | ±10μm | ±30μm | ||||||
| Resolution | 0.1μm | 0.1μm | 0.1μm | 1μm | 1μm | 1μm | ||||||
| Measurement method | Non-contact laser scanning | |||||||||||
| Light source | Semiconductor laser (max. 1 mW), red (650 nm), Class 2 continuous wave | |||||||||||
| Protection | Dust-proof construction | |||||||||||
[*1] A large-diameter measurement system for larger ranges is also available.
[*1] Accuracy when the averaging count within a specified area is set to at least the following:
Up to LDM-303H: 256 / LDM-304H and above: 512
Single-axis detector, separate type (400-scan type)
| Model | LDM-303H-SP | LDM-304H-SP | LDM-305H-SP | LDM-306H-SP | ||||
|---|---|---|---|---|---|---|---|---|
| CAD files | ||||||||
| Measurement range | 0.3–30 mm | 0.5–90 mm | 1–180 mm | 2–300 mm[*1] | ||||
| Measurement accuracy[*2] | ±2μm | ±5μm | ±10μm | ±30μm | ||||
| Resolution | 0.1μm | 1μm | 1μm | 1μm | ||||
| Measurement method | Non-contact laser scanning | |||||||
| Light source | Semiconductor laser (max. 1 mW), red (650 nm), Class 2 continuous wave | |||||||
| Protection | Dust-proof construction | |||||||
[*1] A large-diameter measurement system for larger ranges is also available.
[*1] Accuracy when the averaging count within a specified area is set to at least the following:
Up to LDM-303H: 256 / LDM-304H and above: 512
Single-axis detector, separate type (2000-scan type)
| Model | LDM-303HS-SP | LDM-304HS-SP | ||
|---|---|---|---|---|
| CAD files | ||||
| Measurement range | 0.3–30 mm | 0.5–90 mm | ||
| Measurement accuracy[*2] | ±2μm | ±5μm | ||
| Resolution | 0.1μm | 1μm | ||
| Measurement method | Non-contact laser scanning | |||
| Light source | Semiconductor laser (max. 1 mW), red (650 nm), Class 2 continuous wave | |||
| Protection | Dust-proof construction | |||
[*1] Accuracy when the averaging count within a specified area is set to at least the following:
Up to LDM-303H: 256 / LDM-304H and above: 512
Orthogonal two-axis detector
| Model | LDM-302H-XY | LDM-303H-XY | LDM-304H-XY | LDM-305H-XY | LDM-306H-XY | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| CAD files | ||||||||||
| Measurement range | 0.05–5 mm | 0.3–30 mm | 0.5–90 mm | 1–180 mm | 2–300 mm | |||||
| Measurement accuracy[*2] | ±1μm | ±2μm | ±5μm | ±10μm | ±30μm | |||||
| Resolution | 0.1μm | 0.1μm | 1μm | 1μm | 1μm | |||||
| Measurement method | Non-contact laser scanning | |||||||||
| Light source | Semiconductor laser (max. 1 mW), red (650 nm), Class 2 continuous wave | |||||||||
| Protection | Dust-proof construction | |||||||||
[*1] A large-diameter measurement system for larger ranges is also available.
[*1] Accuracy when the averaging count within a specified area is set to at least the following:
Up to LDM-303H: 256 / LDM-304H and above: 512
Oscillating detector for full-circumference measurement
| Model | LDM-303H-SP LDM-703A[*2] | LDM-304H LDM-704A[*2] | LDM-305H LDM-705[*2] | |||
|---|---|---|---|---|---|---|
| CAD files | ||||||
| Measurement range | 0.3–30 mm | 0.5–90 mm | 1–180 mm | |||
| Measurement accuracy[*2] | ±2μm | ±5μm | ±10μm | |||
| Resolution | 0.1μm | 1μm | 1μm | |||
| Measurement method | Non-contact laser scanning | |||||
| Light source | Semiconductor laser (max. 1 mW), red (650 nm), Class 2 continuous wave | |||||
| Protection | Dust-proof construction | |||||
[*1] Accuracy when the averaging count within a specified area is set to at least the following:
Up to LDM-303H: 256 / LDM-304H and above: 512
[*2] Model number of the oscillating unit alone.
Display Unit
Standard Type
| Model | LDM-130 | LDM-130EX | |||
|---|---|---|---|---|---|
| CAD files | |||||
| Sampling rate | 400/s, 2000/s[*1] | ||||
| Averaging count | 1–2048 (12 steps) | ||||
| Measurement mode | Measurement between any edges | ||||
| Measurement method | Display digits | Up to 5 digits | |||
| Calculations | ― | (1) Average (2) Difference (3) Ratio (4) Large-diameter measurement | |||
| Product position monitor | 8 LEDs | 8 LEDs (X and Y axes each) | |||
| Recorder | Output | Max. ±10 V DC, resolution: 12 bits (approx. 10 mV) Gain: 1 μV–1000 mV, impedance: approx. 100 Ω, deviation/absolute value switchable | |||
| External control connection | Digital deviation (analog also available). Connection to the DAC+88 is via RS232C. | ||||
| Center value setting | 5 digits | ||||
| Upper/lower tolerance settings | 4 digits each | ||||
| Contact output | Upper / lower limit contact output | 1a contact × 2 | |||
| Error contact output | 1b contact (closed when power is off) | ||||
| Contact rating | 250 V AC, 2 A (resistive load) | ||||
| Contact rating | ○ | Yes (common to X and Y axes) | |||
| Hold terminal | ○ | Yes (common to X and Y axes) | |||
| Self-diagnosis | ○ | ||||
| Trigger mode | × | ||||
| Offset function | × | ||||
| Zero-set function | ○ | Yes (difference measurement only) | |||
| Unit switching | × | ||||
| Program function | × | ||||
| Graph function | × | ||||
| RS232C communication | ○ | ||||
| RS485 communication | ○ | ||||
| BCD output | Option (RS485 is removed when installed) | ||||
| Other communication | Option (CC-Link, EtherNet/IP) | ||||
| Cable length to detector | Standard 5 m / max. 120 m (LDM-201/202 required for 30 m or more) | ||||
| Power supply | 90–240 V AC universal power supply, 50/60 Hz | ||||
| Power consumption | Approx. 20 VA | ||||
[*1] Fixed by the detector (2000/s is HS Series only)
High-Speed Scan Type
| Model | LDM-210 | LDM-210EX | |||
|---|---|---|---|---|---|
| CAD files | |||||
| Sampling rate | 400/s, 2000/s[*1] | ||||
| Averaging count | 1–2048 (12 steps) | ||||
| Measurement mode | Measurement between any edges | ||||
| Measurement method | Display digits | Up to 5 digits | |||
| Calculations | EX mode available when two units are used | (1) Average (2) Difference (3) Ratio (4) Large-diameter measurement | |||
| Product position monitor | 8 LEDs | 8 LEDs (X and Y axes each) | |||
| Recorder | Output | Max. ±10 V DC, resolution: 12 bits (approx. 10 mV) Gain: 1 μV–1000 mV, impedance: approx. 100 Ω, deviation/absolute value switchable | |||
| External control connection | Digital deviation (analog also available). Connection to the DAC+88 is via RS232C. | ||||
| Center value setting | 5 digits | ||||
| Upper/lower tolerance settings | 5 digits each | ||||
| Contact output | Upper / lower limit contact output | 1a contact × 2 | |||
| Error contact output | 1b contact (closed when power is off) | ||||
| Contact rating | 250 V AC, 2 A (resistive load) | ||||
| Contact rating | ○ | Yes (common to X and Y axes) | |||
| Hold terminal | ○ | Yes (common to X and Y axes) | |||
| Self-diagnosis | ○ | ||||
| Trigger mode | × | ||||
| Offset function | ○ | × | |||
| Zero-set function | × | Yes (difference measurement only) | |||
| Unit switching | × | ||||
| Program function | × | ||||
| Graph function | × | ||||
| RS232C communication | ○ | ||||
| RS485 communication | × | ||||
| BCD output | Options | ||||
| Other communication | × | ||||
| Cable length to detector | Standard 5 m / max. 120 m (LDM-201/202 required for 30 m or more) | ||||
| Power supply | 90–240 V AC universal power supply, 50/60 Hz | ||||
| Power consumption | 11 VA or less | Approx. 20 VA | |||
[*1] Fixed by the detector (2000/s is HS Series only)
Type with Outer Diameter Control
| Model | LDM-130C | LDM-130EXC | |||
|---|---|---|---|---|---|
| CAD files | |||||
| Sampling rate | 400/s, 2000/s[*1] | ||||
| Averaging count | 1–2048 (12 steps) | ||||
| Measurement mode | Measurement between any edges | ||||
| Measurement method | Display digits | Up to 5 digits | |||
| Calculations | EX mode available when two units are used | (1) Average (2) Difference (3) Ratio (4) Large-diameter measurement | |||
| Product position monitor | 8 LEDs | 8 LEDs (X and Y axes each) | |||
| Recorder | Output | Max. ±10 V DC, resolution: 12 bits (approx. 10 mV) Gain: 1 μV–1000 mV, impedance: approx. 100 Ω, deviation/absolute value switchable | |||
| External control connection | Built-in P.I. control (equivalent to DAC-96) | ||||
| Center value setting | 5 digits | ||||
| Upper/lower tolerance settings | 4 digits each | ||||
| Contact output | Upper / lower limit contact output | 1a contact × 4 | |||
| Error contact output | 1b contact (closed when power is off) | ||||
| Contact rating | 250 V AC, 2 A (resistive load) | ||||
| Contact rating | ○ | Yes (common to X and Y axes) | |||
| Hold terminal | ○ | Yes (common to X and Y axes) | |||
| Self-diagnosis | ○ | ||||
| Trigger mode | × | ||||
| Offset function | × | ||||
| Zero-set function | × | Yes (difference measurement only) | |||
| Unit switching | × | ||||
| Program function | × | ||||
| Graph function | × | ||||
| RS232C communication | ○ | ||||
| RS485 communication | ○ | ||||
| BCD output | Option (RS485 is removed when installed) | ||||
| Other communication | Option (CC-Link, EtherNet/IP) | ||||
| Cable length to detector | Standard 5 m / max. 120 m (LDM-201/202 required for 30 m or more) | ||||
| Power supply | 90–240 V AC universal power supply, 50/60 Hz | ||||
| Power consumption | Approx. 30 VA | ||||
[*1] Fixed by the detector (2000/s is HS Series only)
Product Variations
Product Variations
A lineup for everything from fine to large diameters, matched to the measured product and line conditions. Below are the main specifications of the LDM Series, including measurement method, accuracy, and output.
Variations by Size
Single-axis detector, standard type
Applications and features: Outer diameter gauge for measurement in one direction. Available in two scan types.
Single-axis detector, separate type
Applications and features: Separate type in which the laser transmitter and receiver can be installed at any distance apart.
Orthogonal two-axis detector
Applications and features: Measures in two directions at once. Also suitable for average-value control and elliptical products.
Oscillating detector for full-circumference measurement
Applications and features: Measures the full 360° circumference inline. Can also detect maximum and minimum values.
Single-axis display unit
Applications and features: Manages outer diameter with upper and lower tolerance settings and alarm output. Equipped with external I/O.
Two-axis display unit, standard type
Applications and features: Compact design that shows a selected value (X axis, Y axis, average, etc.).
Two-axis display unit, multi-function type
Applications and features: Trigger function and condition settings for multiple products as standard. Also supports three-axis measurement.
Display unit with outer diameter control
Applications and features: All-in-one display unit with an outer diameter control function equivalent to the DAC-96.
Specification Table
| Measurement method | Non-contact laser scanning |
|---|---|
| Measurement range | 0.02–300 mm (varies by model) |
| Light source | Semiconductor laser (max. 1 mW), red light (650 nm), Class 2 continuous wave |
| Scan rate | 400 / 2000 scans/s |
| Repeatability | ±0.3 μm to ±5 μm (varies by model) |
| Measurement accuracy | ±1 μm to ±30 μm (varies by model) |
| External I/O | Analog / RS232C / RS485, BCD output (option). Availability depends on the display unit model. |
| External communication unit (option) | CC-Link / Ethernet/IP |
| Power supply | 90–240 V AC universal power supply, 50/60 Hz, approx. 20 VA |
| Operating environment | Temperature: 0–45°C, humidity: 35–85% RH (non-condensing) |
| Options | Air purge unit / external display unit / calibration jig set |
FAQ
FAQ
Can it measure transparent tubing or glass?
Transparent products can be difficult for a laser to detect. We offer a transparent-object version that measures the outer diameter of such products accurately. Please contact us for details.
Is it affected by sunlight or room lighting?
Outer diameter gauges with a laser light source are largely unaffected by sunlight and room lighting. They can be used normally in a typical factory.
Can it measure while the wire moves up and down?
Because it measures by high-speed scanning, it can generally measure outer diameter even when the wire is vibrating up and down. However, this vibration can cause small measurement errors. If you need higher accuracy, consider LED outer diameter measurement.
Can it connect to our existing PLC?
We offer a wide range of communication options. Choose the option that suits your system, and the gauge can communicate with your PLC.
How often and how should it be calibrated?
We recommend calibration once a year. Calibration jig sets are available for each model, so you can also calibrate in-house. If you need a calibration certificate, please ask us to calibrate it.
Can we try it before purchasing?
We have demo units available for inline testing before purchase. Models and quantities are limited, so please contact us in advance when you are considering a purchase.
What after-sales support do you offer?
Maintenance and repairs are handled by a dedicated department. In addition to sending the product to us, we can also work on site at your factory.
Can it measure shapes other than round?
Each type of non-contact outer diameter gauge has its strengths and limitations. Whether a shape can be measured depends on the shape, so please contact us first.
Documents for Evaluation
- Download
For case studies and products,