PRF Series Profile Extrusion Control Unit
Overview
A control unit that keeps the shape of extruded profiles constant in plastic extrusion. It consists of the PRF-10H/PRF-40H edge sensors and the PRF-93 controller, and is used together with the DAC-96 outer diameter control unit.
Features of the PRF Series
- The detection head is installed right after the extruder and measures the difference between the extruded profile and the reference value without contact.
- Applying the correction amount as a voltage controls the extruder or take-up directly.
- Keeping the profile shape constant improves quality and yield and reduces material use.
Product Lineup
Product Variations

Edge sensors
PRF-10H / PRF-40H
Applications and features: Non-contact infrared optical fiber method.
Measurement area: 1 mm × 20 mm (PRF-10H), 1 mm × 40 mm (PRF-40H).

Controller
PRF-93
Applications and features: Shows the deviation on an analog meter
and outputs it as an analog voltage and upper/lower limit contacts.
Principle
Principle

Calculates the correction from the change in L
The sensor measures the distance L, performs proportional-integral calculation according to its change, and adds the calculated correction to the motor speed command voltage of the extruder or take-up.
For example, when the outer diameter increases, L decreases, so a correction voltage is applied to raise the take-up speed until the set outer diameter is reached.
Installation Example
Installation Example

Connection from the edge sensor to the take-up motor
The diagram shows an installation example for controlling the take-up. The edge sensor is installed right after the extruder with mounting brackets (supplied separately) and connected via the PRF-93 controller and DAC-96 control unit to the motor controller (take-up speed setter) of the take-up motor.
Click the diagram to enlarge it.
Specifications
Product Specification
PRF Series
| Edge sensors | Model | PRF-10H | PRF-40H | ||
|---|---|---|---|---|---|
| CAD files | |||||
| Method | Non-contact infrared optical fiber method | ||||
| Measurement area | 1mm×20mm | 1mm×40mm | |||
| Resolution | 1µm | 3µm | |||
| Accuracy | ±5µm | ±10µm | |||
| Operating temperature | Max. 300°C | Max. 250°C | |||
| Controller | Model | PRF-93 | |||
| CAD files | |||||
| Deviation display | Analog meter ±0.5 mm (PRF-10H) / ±2 mm (PRF-40H) | ||||
| Deviation output | Analog voltage ±4 V/±0.5 mm (PRF-10H) / ±4 V/±2 mm (PRF-40H) | ||||
| Upper/lower limit contacts | Multi-step setting; contact output 250 V, 1 A | ||||
| Power supply | 100–240 V AC, 50/60 Hz, 10 VA | ||||
| Peripherals and Accessories | Control unit | Outer diameter control unit: uses the DAC-96 | |||
| Edge sensor mounting brackets | Supplied separately | ||||