CP Series Capacitance Monitor
Overview
Measures the capacitance of insulated wire produced on continuous extrusion lines online and continuously. Detectors are available for a range of product diameters, from fine to thick wire.
Features of the Capacitance Monitor
- A forced water supply and drainage mechanism supports high line speeds.
- Guard electrodes provide stable measurement that resists wire vibration.
- The measured value and the deviation from the preset value are shown digitally at the same time.
- Supports capacitance control of insulated wire based on the deviation.
Detector
Detector

Three models to match wire diameter
Three detectors are available: CP-05B, CP-09B, and CP-15B, with recommended cable diameters of Φ5 mm, Φ9 mm, and Φ15 mm respectively.
The forced water supply and drainage mechanism and guard electrodes support continuous measurement on the production line. See the specifications for operating conditions such as standard water conductivity.
Display Unit
Display

Check the measured value and deviation at the same time
You can set any tolerance range (alarm level) for deviation from the preset value, with relay signal output to external equipment.
Analog output of the measured value or deviation and control voltage output (±10 V DC) are standard, enabling capacitance control based on the deviation.
External communication and output
RS232C is standard; RS485 and BCD output are available as options. Analog and control outputs are isolated.
Equipment Configuration
System
For correct measurement, connect each device as shown below. Missing connections can cause large measurement errors.

Specifications
Product Specification
Detector
| Model | CP-05B | CP-09B | CP-15B | |||
|---|---|---|---|---|---|---|
| Recommended cable diameter | Φ5mm | Φ9mm | Φ15mm | |||
| Through-hole diameter | Φ8mm | Φ15mm | Φ30mm | |||
| Standard water conductivity | 1 mS/cm or less (depends on water temperature, dissolved substances, etc.); recommended: 0.5 mS/cm or less | |||||
| CAD files | ||||||
Relay unit
Display Unit
| Model | CPM-401B | |
|---|---|---|
| Measurement range | 0–400 pF/m (range can be extended on request) | |
| Measurement accuracy | ±0.2% of reading or ±0.2 pF/m, whichever is greater | |
| Resolution | 0.1pF/m | |
| Sampling rate | 500/s | |
| Display: capacitance | 4-digit green 7-segment LED | |
| Display: capacitance deviation | 4-digit red 7-segment LED and LED bar graph (full scale selectable: ±10 pF/m or ±100 pF/m) | |
| Target value setting | 4-digit digital switch | |
| Upper/lower limit setting | 3-digit digital switch | |
| Averaging | Moving average (1–5000, in 1/2/5 steps) | |
| Zero adjustment | Automatic adjustment with the ZERO switch on the front panel | |
| Analog output | Capacitance or deviation output within ±10 V DC, selectable gain, isolated output | |
| Upper / lower limit contact output | Red LED indication and 1a contact output for upper and lower limits (250 V AC, 2 A, resistive load) | |
| BCD output | Options | |
| External communication | RS232C (standard) or RS485 (option) | |
| Control method | Simple proportional control | |
| Control output | ±10 V DC voltage output, isolated | |
| Power supply | 90–240 V AC universal power supply, 50/60 Hz, 10 VA | |
| CAD files | ||
Calibration Capacitor
Calibration

For capacitance calibration
A device for calibrating the capacitance monitor. An electrode is mounted in the center of a glass body; through the water, the detection electrode and the calibration capacitor's center electrode form a capacitor with the glass as its dielectric.
After purchase, traceability for the calibration capacitor is available on request (charged separately).
Calibration capacitor specifications
Calibration Capacitor
| Model | CPR-05 | CPR-09 | CPR-15 | |||
|---|---|---|---|---|---|---|
| Compatible detectors | CP-05B | CP-09B | CP-15B | |||
| Material | Dielectric: Pyrex® glass; electrode: SUS304 | |||||
| Reference capacitance | Stated on each calibration capacitor | |||||
| Uncertainty | Within ±0.2% of the stated reference capacitance | |||||
| Temperature | Reference temperature: 23±5°C; guaranteed temperature: 15–35°C | |||||
| Measuring instrument accuracy | 0.05% | |||||
| Measuring instrument frequency | 1MHz | |||||
| CAD files | ||||||