DAC Series

Outer Diameter Control Unit

Feedback control of the extruder and take-up
based on the outer diameter gauge signal.

  • Constant outer diameter control
  • Automatic start-up
  • RS232C support
DAC+88 and DAC-96 outer diameter control units

DAC Series Outer Diameter Control Unit

Overview

Receives signals from an outer diameter gauge or other dimension gauge and outputs feedback signals to the extruder and take-up to keep the outer diameter constant.

Three models are available: the DAC+88, which automates start-up with a learning function; the DAC-93, for sites where the distance between the extruder and the outer diameter gauge is long; and the DAC-96, for sites where that distance is short.

Product Variations

Product Variations

DAC+88

With automatic start-up

DAC+88

Applications and features: Automatically learns the extrusion/take-up speed ratio with each run.
Reduces losses at start-up.

DAC-93

Step control type

DAC-93

Applications and features: For sites where the extruder is far from the outer diameter gauge.
Cancels the time delay caused by the distance.

DAC-96

P.I. control type

DAC-96

Applications and features: For sites where the extruder is close to the outer diameter gauge.
Enables real-time feedback control.

DAC+88 Outer Diameter Control Unit with Automatic Start-Up

Auto Start-up Control

DAC+88 Outer Diameter Control Unit with Automatic Start-Up

Learns the speed ratio automatically to simplify start-up

With each run, the unit automatically learns the ratio of extruder screw speed to take-up speed needed to keep the outer diameter constant.
Reducing losses at start-up simplifies operation.

Features of the DAC+88

  • The control amount is calculated automatically, so no adjustment is needed while the line is running.
  • Manual, automatic, start-up, and deceleration operations are available through external contact input terminals.
  • All operations can be performed from an external computer via the RS232C interface.

Learning Operation

Learning Operation

Graph comparing take-up speed, extrusion speed, and target outer diameter during the first line start-up and a start-up after learning

Outer diameter is more stable after learning

Automatic control keeps the outer diameter within a certain range even before learning, but after learning the outer diameter is more stable.
Line characteristics are learned for each product and up to 100 sets are stored, so there is no need to re-enter data when changing products.

DAC-93 Step Control Outer Diameter Control Unit

Step Control

DAC-93 Step Control Outer Diameter Control Unit

Cancels the time delay caused by distance

Deviation information is input from the laser outer diameter gauge, and A-phase and B-phase pulses from a rotary encoder.
Feedback control is achieved by setting the distance between the extruder and the outer diameter gauge and the pulse rate of the rotary encoder.

Features of the DAC-93

  • Ideal for sites where the distance between the extruder and the outer diameter gauge is long.
  • Step control cancels the time delay caused by the distance from the extruder to the measurement point.
  • Switch between automatic and manual control with switches, contacts, or RS232C or RS485 commands.

Basic Operation of the DAC-93

Basic Operation

Diagram of the DAC-93 control voltage at power-on and when switching between automatic and manual

Basic operation with automatic/manual/reset switching

The control output voltage can be held when switching from automatic to manual control.
When the control output voltage is shorted on switching to manual control, a time constant can be applied so that no sudden load is placed on the extruder or take-up.

DAC-93 Operation Timing

Operation Timing

Timing diagram of the DAC-93 showing the relationship between deviation voltage, alarm level, ALARM TIME, and DEAD TIME

Adds a step voltage when the alarm level is exceeded

During automatic control, the unit monitors whether the deviation voltage input exceeds the alarm level. If it does, a step voltage (P × deviation input voltage) is added to the control voltage output.
After the DEAD TIME following the addition of the step voltage, monitoring of the deviation voltage input resumes.

DAC-96 P.I. Control Outer Diameter Control Unit

P.I. Control

DAC-96 P.I. Control Outer Diameter Control Unit

Real-time feedback control

Deviation information is input from the laser outer diameter gauge, and the line speed voltage from the production line.
Feedback control is achieved by setting appropriate P (proportional) and I (integral) values.

Features of the DAC-96

  • Ideal for sites where the distance between the extruder and the outer diameter gauge is short.
  • P.I. control enables real-time feedback control.
  • Switch between automatic and manual control with switches, contacts, or RS232C or RS485 commands.

Basic Operation of the DAC-96

Basic Operation

Diagram of the DAC-96 control voltage, voltage hold, and reset time constant at power-on and during automatic, manual, and reset

Basic operation with automatic/manual/reset switching

The control output voltage can be held when switching from automatic to manual control.
When the control output voltage is shorted on switching to manual control, a time constant can be applied so that no sudden load is placed on the extruder or take-up.

Specifications

Product Specification

DAC Series
Specifications of the DAC Series outer diameter control unit
ModelDAC+88DAC-93DAC-96
CAD files DXF PDF DXF PDF DXF PDF
Control method Parameter-setting control Delay-time step control P/I/SPEED control
Automatic start-up function ○ × ×
Compatible outer diameter gauges Our products only Any (analog deviation output required) Any (analog deviation output required)
Signal inputInput type Extrusion/take-up speed voltage input Outer diameter deviation input Outer diameter deviation/speed voltage input
Isolation ○
Voltage range Extrusion input: 0 to +10 V DC
Take-up input: 0 to +10 V DC
Outer diameter input: ±10 V DC
Speed input: 0 to +10 V DC
Outer diameter input: ±10 V DC
Speed input: 0 to +10 V DC
Input resistance 200kΩ
Gain selection × 10 µm–10 mm/V (selectable) ×
Signal outputOutput type Extrusion/take-up speed voltage output Control output Control output
Output method Absolute value control Correction value control Correction value control
Isolation ○
Voltage range 0 to +10 V DC per output DC±10V DC±10V
Max. current 0 to +10 mA DC per output DC±20mA DC±20mA
Output resistance 10 Ω or less per output 6 Ω or less 6 Ω or less
Limit voltage Configurable
SettingsItems System data: 11 types / work data: 12 types Alarm level, P P, I
Programming function ○ × ×
Operation buttons Manual / automatic / start-up / deceleration Manual / automatic / reset Manual / automatic / reset
External operation input ○
Length measurement pulse signal Not required Required (speed input also possible) Not required
Main display Settings and operating status shown on LCD Control output shown on LED bar graph Control output shown on LED bar graph
External communication RS232C RS232C, RS485 RS232C, RS485 (standard)
CC-Link, EtherNet/IP (option)
Power supply 90–240 V AC, 50/60 Hz, universal power supply
Power consumption 10 VA or less 8 VA or less 8 VA or less

Documents for Evaluation

- Download

For case studies and products,
please feel free to contact us.

Have a question?
Our team is ready to help.

Contact

Tel. +81-42-645-8920

Hours: 9:00–17:30 JST, Monday–Friday (excluding Japanese public holidays)

General Inquiries

Contact

Contact us about products, quotations, or documentation.

Contact Us Contact Us

Request a Quote

Quotation

Tell us about your application, and we will prepare a quotation.

Request a Quote

Brochures & Manuals

Download

Find the information you need to select and evaluate our products.

Download