DAC Series Outer Diameter Control Unit
Overview
Receives signals from an outer diameter gauge or other dimension gauge and outputs feedback signals to the extruder and take-up to keep the outer diameter constant.
Three models are available: the DAC+88, which automates start-up with a learning function; the DAC-93, for sites where the distance between the extruder and the outer diameter gauge is long; and the DAC-96, for sites where that distance is short.
Product Variations
Product Variations

With automatic start-up
DAC+88
Applications and features: Automatically learns the extrusion/take-up speed ratio with each run.
Reduces losses at start-up.

Step control type
DAC-93
Applications and features: For sites where the extruder is far from the outer diameter gauge.
Cancels the time delay caused by the distance.

P.I. control type
DAC-96
Applications and features: For sites where the extruder is close to the outer diameter gauge.
Enables real-time feedback control.
DAC+88 Outer Diameter Control Unit with Automatic Start-Up
Auto Start-up Control

Learns the speed ratio automatically to simplify start-up
With each run, the unit automatically learns the ratio of extruder screw speed to take-up speed needed to keep the outer diameter constant.
Reducing losses at start-up simplifies operation.
Features of the DAC+88
- The control amount is calculated automatically, so no adjustment is needed while the line is running.
- Manual, automatic, start-up, and deceleration operations are available through external contact input terminals.
- All operations can be performed from an external computer via the RS232C interface.
Learning Operation
Learning Operation

Outer diameter is more stable after learning
Automatic control keeps the outer diameter within a certain range even before learning, but after learning the outer diameter is more stable.
Line characteristics are learned for each product and up to 100 sets are stored, so there is no need to re-enter data when changing products.
DAC-93 Step Control Outer Diameter Control Unit
Step Control

Cancels the time delay caused by distance
Deviation information is input from the laser outer diameter gauge, and A-phase and B-phase pulses from a rotary encoder.
Feedback control is achieved by setting the distance between the extruder and the outer diameter gauge and the pulse rate of the rotary encoder.
Features of the DAC-93
- Ideal for sites where the distance between the extruder and the outer diameter gauge is long.
- Step control cancels the time delay caused by the distance from the extruder to the measurement point.
- Switch between automatic and manual control with switches, contacts, or RS232C or RS485 commands.
Basic Operation of the DAC-93
Basic Operation

Basic operation with automatic/manual/reset switching
The control output voltage can be held when switching from automatic to manual control.
When the control output voltage is shorted on switching to manual control, a time constant can be applied so that no sudden load is placed on the extruder or take-up.
DAC-93 Operation Timing
Operation Timing

Adds a step voltage when the alarm level is exceeded
During automatic control, the unit monitors whether the deviation voltage input exceeds the alarm level. If it does, a step voltage (P × deviation input voltage) is added to the control voltage output.
After the DEAD TIME following the addition of the step voltage, monitoring of the deviation voltage input resumes.
DAC-96 P.I. Control Outer Diameter Control Unit
P.I. Control

Real-time feedback control
Deviation information is input from the laser outer diameter gauge, and the line speed voltage from the production line.
Feedback control is achieved by setting appropriate P (proportional) and I (integral) values.
Features of the DAC-96
- Ideal for sites where the distance between the extruder and the outer diameter gauge is short.
- P.I. control enables real-time feedback control.
- Switch between automatic and manual control with switches, contacts, or RS232C or RS485 commands.
Basic Operation of the DAC-96
Basic Operation

Basic operation with automatic/manual/reset switching
The control output voltage can be held when switching from automatic to manual control.
When the control output voltage is shorted on switching to manual control, a time constant can be applied so that no sudden load is placed on the extruder or take-up.
Specifications
Product Specification
DAC Series
| Model | DAC+88 | DAC-93 | DAC-96 | ||||
|---|---|---|---|---|---|---|---|
| CAD files | |||||||
| Control method | Parameter-setting control | Delay-time step control | P/I/SPEED control | ||||
| Automatic start-up function | ○ | × | × | ||||
| Compatible outer diameter gauges | Our products only | Any (analog deviation output required) | Any (analog deviation output required) | ||||
| Signal input | Input type | Extrusion/take-up speed voltage input | Outer diameter deviation input | Outer diameter deviation/speed voltage input | |||
| Isolation | ○ | ||||||
| Voltage range | Extrusion input: 0 to +10 V DC Take-up input: 0 to +10 V DC |
Outer diameter input: ±10 V DC Speed input: 0 to +10 V DC |
Outer diameter input: ±10 V DC Speed input: 0 to +10 V DC |
||||
| Input resistance | 200kΩ | ||||||
| Gain selection | × | 10 µm–10 mm/V (selectable) | × | ||||
| Signal output | Output type | Extrusion/take-up speed voltage output | Control output | Control output | |||
| Output method | Absolute value control | Correction value control | Correction value control | ||||
| Isolation | ○ | ||||||
| Voltage range | 0 to +10 V DC per output | DC±10V | DC±10V | ||||
| Max. current | 0 to +10 mA DC per output | DC±20mA | DC±20mA | ||||
| Output resistance | 10 Ω or less per output | 6 Ω or less | 6 Ω or less | ||||
| Limit voltage | Configurable | ||||||
| Settings | Items | System data: 11 types / work data: 12 types | Alarm level, P | P, I | |||
| Programming function | ○ | × | × | ||||
| Operation buttons | Manual / automatic / start-up / deceleration | Manual / automatic / reset | Manual / automatic / reset | ||||
| External operation input | ○ | ||||||
| Length measurement pulse signal | Not required | Required (speed input also possible) | Not required | ||||
| Main display | Settings and operating status shown on LCD | Control output shown on LED bar graph | Control output shown on LED bar graph | ||||
| External communication | RS232C | RS232C, RS485 | RS232C, RS485 (standard) CC-Link, EtherNet/IP (option) |
||||
| Power supply | 90–240 V AC, 50/60 Hz, universal power supply | ||||||
| Power consumption | 10 VA or less | 8 VA or less | 8 VA or less | ||||