EM Series Eccentricity Monitor
Overview
A laser measures the position of the wire and magnetism measures the center of the conductor inside it; digital signal processing then calculates the eccentricity. The monitor is designed for wire with insulation over a round conductor.
Features of the Eccentricity Monitor
- Non-contact measurement does not damage the cable.
- Suitable for insulated wire of many diameters, from fine to large.
- No mechanical moving parts, so maintenance is easy.
Panel Computer (Display Unit)
Display

Check eccentricity and wire position in real time
The display unit is a panel computer with touch-panel operation. Wire position and eccentricity are shown graphically, and the display can be switched between eccentricity and wall thickness.
On the settings screen, you can set target and tolerance values for the measurement data, as well as the wire length counted by an encoder.
Recording and external communication
Measurement data for each wire can be recorded in CSV format on CF memory. Online operation with an external computer via RS232C is supported, and data can be managed centrally via RS485 (option).
System Configuration
System

Installation on the Production Line

<Installation note> Be sure to ground the conductor, conductor feeder, extruder, eccentricity monitor, water tank, and take-up. Also be sure to connect the conductor to ground.
Specifications
Product Specification
Common Specifications
| Measured object | Wire with insulation over a round conductor |
|---|---|
| Operating environment | Temperature 5–40°C, humidity 35–85% RH (non-condensing) |
| Analog output | Eccentricity (X, Y, R, θ axes) Outer diameter deviation (X, Y, average) Outer diameter absolute value (X, Y, average) |
| Alarm output (relay) | Outer diameter upper limit, outer diameter lower limit, excess eccentricity, error (abnormal position) |
| File output | Measurement data can be saved to CF, USB memory, etc. |
| RS232C | 8 data bits, 1 stop bit, no parity 19200 bps recommended |
| RS485 | Available as an option |
| Grounding resistance | Class 3 grounding under Japanese standards (100 Ω or less) |
| AC power | 90–240 V AC, 50/60 Hz, 50 VA or less |
Specifications by Model
Detection Unit
| Model | EM-302B | EM-303B | EM-304A | EM-304B | ||||
|---|---|---|---|---|---|---|---|---|
| Finished outer diameter | 0.3–5 mm [*1] | 0.3–15 mm | 0.8–30 mm | 0.8–45 mm | ||||
| Conductor outer diameter | 0.1–3 mm [*2] | 0.1–10 mm | 0.5–20 mm | 0.5–35 mm | ||||
| Outer diameter accuracy [*3] | ±0.002mm | ±0.002mm | ±0.005mm | ±0.005mm | ||||
| Eccentricity accuracy | ±0.01 mm [*4] | ±0.015 mm [*4] | ±0.02 mm [*5] | ±0.03 mm [*5] | ||||
| CAD files | ||||||||
[*1] Up to 5 mm can be measured depending on how the unit is used.
[*2] Up to 3 mm can be measured depending on how the unit is used.
[*3] Applies to the X and Y axes individually.
[*4] Measurement accuracy is guaranteed when the wire center is within ±2 mm of the center.
[*5] Measurement accuracy is guaranteed when the wire center is within ±5 mm of the center.
Control, Display, Power Amplifier, and Excitation Units
| Compatible detection unit | EM-302B | EM-303B | EM-304A | EM-304B | ||||
|---|---|---|---|---|---|---|---|---|
| Control unit | EM-200B | |||||||
| CAD files for the control unit | ||||||||
| Display unit | EM-PC2 | |||||||
| Power amplifier | EM-1000 | |||||||
| Excitation unit | EM-800 | Built into the main unit | EM-125 | |||||
| CAD files for the excitation unit | — | |||||||
Documents for Evaluation