OM-01 cable reverse running detection unit

OM Series Pulse Controller

Overview

Control devices that handle A-phase and B-phase pulse signals from rotary encoders and similar sources. Three models are available: the OM-01 detects line reverse running, the OM-02 divides pulses, and the OM-03 distributes pulse signals.

Product Variations

Product Variations

OM-01

Cable reverse running detection unit

OM-01

Applications and features: Detects line reverse running
on continuous extrusion lines.

OM-02

A/B-phase frequency divider (pulse divider)

OM-02

Applications and features: Divides A-phase and B-phase pulses
while keeping their 90° phase difference.

OM-03

Two-system distributor (pulse distributor)

OM-03

Applications and features: Distributes one input signal
to up to five outputs.

OM-01 cable reverse running detection unit

Reverse Detection

OM-01 cable reverse running detection unit

Detects line reverse running on continuous extrusion lines

On extrusion lines, the material (product) can move backward (reverse running) when a bundle is cut or the product breaks.
The OM-01 can detect this reverse running.

Detection Method

  • The unit receives A-phase and B-phase pulse signals from a rotary encoder mounted on the line.
  • It counts only backward movement; when the count reaches the threshold (number of pulses) set with the digital switch, it judges the line to be reverse running and outputs a reverse running alarm.
  • When the alarm is output, a contact closes for 500 ms to notify external equipment of the fault.

OM-01 Operation

Operation

Timing diagram of the OM-01 showing the relationship between A-phase input, B-phase input, inhibit gate, count, and contact output in the forward and reverse directions

Counts only backward movement

The diagram shows an example with the count set to 002.
Only backward movement is counted; when the count reaches the set value, the contact output closes for about 500 ms.

OM-02 A/B-Phase Frequency Divider

Pulse Divider

OM-02 A/B-Phase Frequency Divider

Adjusts the frequency for stable operation

When the connected device, such as a counter, cannot handle the output frequency well, the unit adjusts the frequency so it operates stably.
It receives A-phase and B-phase pulses from a rotary encoder and outputs divided pulses while keeping the 90° phase difference. Other manufacturers sometimes call this a pulse divider.

Example Use of the Divider

Our AD-700 counting event printer cannot count inputs of 2 kHz or more. Dividing a 100 kHz signal by 100, or a 10 kHz signal by 10, converts it to 1 kHz so the AD-700 can count correctly.

OM-02 Operation

Operation

Timing diagram of the OM-02 showing input and divide-by-10 and divide-by-100 A-phase and B-phase outputs with two-phase and single-phase input

Divided output with two-phase and single-phase input

The diagram shows divide-by-10 and divide-by-100 outputs with two-phase and single-phase input. With single-phase input, the B-phase output is undefined.
If the phase relationship of the A-phase and B-phase inputs is reversed, the phase relationship of the divided A-phase and B-phase outputs is also reversed.

OM-03 Two-System Distributor

Pulse Distributor

OM-03 Two-System Distributor

Distributes one input signal to up to five outputs

Used when pulse signals (A-phase and B-phase) from an encoder or length measuring device are to be shared by several devices.
Input pulse signals are received as open collector signals and output as open collector signals, so the unit connects flexibly to many devices regardless of the input voltage level.
It has two systems, each with five distribution output circuits for one input.

Specifications

Product Specification

OM-01 cable reverse running detection unit
OM-01 specifications
ModelOM-01
Power supply+12 V DC / 0.5 A (can be modified)
Settings3-digit digital switch
Contact outputa contact, 500 ms one-shot, 240 V AC, 1 A (resistive load)
Count inputA-phase/B-phase
Max. count rate5 kHz (can be modified)
DisplayPower LED and reverse running indicator LED
Inhibit gateOutput inhibited when terminals are shorted or at "L" level (5 V DC CMOS level)
CAD files DXF PDF

The CAD drawing is shared by the OM-01, OM-02, and OM-03.

OM-02 A/B-Phase Frequency Divider
OM-02 specifications
ModelOM-02
Power supply+12 V DC / 0.5 A (can be modified)
Division ratioDivide by 10 and divide by 100
Divided outputOpen collector output
Count inputA-phase/B-phase
Max. count rate10 kHz (can be modified)
Single-phase/two-phase switchingSwitched with a jumper on the internal board
CAD files DXF PDF

The CAD drawing is shared by the OM-01, OM-02, and OM-03.

OM-03 Two-System Distributor
OM-03 specifications
ModelOM-03
Power supply+12 V DC / 0.5 A (can be modified)
Input2 systems (built-in 4.7 kΩ pull-up resistors)
Output
Max. count rate10 kHz (can be modified)
CAD files DXF PDF

The CAD drawing is shared by the OM-01, OM-02, and OM-03.

Documents for Evaluation

- Download

For case studies and products,
please feel free to contact us.

Have a question?
Our team is ready to help.

Contact

Tel. +81-42-645-8920

Hours: 9:00–17:30 JST, Monday–Friday (excluding Japanese public holidays)

General Inquiries

Contact

Contact us about products, quotations, or documentation.

Contact Us Contact Us

Request a Quote

Quotation

Tell us about your application, and we will prepare a quotation.

Request a Quote

Brochures & Manuals

Download

Find the information you need to select and evaluate our products.

Download