Built to Order

RS485 System

Connects multiple gauges in a multipoint network
for setup, monitoring, and data management on a panel PC.

  • Multipoint serial connection
  • Data saved as CSV
  • Alarm output
RS485 system hardware: a D-sub 9-pin connector and unit

RS485 System

Overview

A communication system for multipoint serial connection of our equipment, including laser outer diameter gauges, irregularity detectors, capacitance monitors, and joint detectors. Settings, commands, and data management are handled from a panel PC.

Connection diagram of an RS485 system

System Diagram

Connection diagram of a panel PC connected by RS485 cables to the display units and relay units of an outer diameter gauge, eccentricity monitor, capacitance monitor, outer diameter irregularity detector, joint detector, defect marking unit, and more

Connecting the Panel PC and Gauges

The diagram shows an example in which the display units and relay units of the gauges on an extrusion line are connected to a panel PC with RS485 cables.
Click the diagram to enlarge it.

Feature

Features

  • Measured values from each gauge are shown digitally for real-time monitoring. Graph display is also available.
  • Data from the start to the end of measurement is saved in a CSV file, and quality control charts can be created from the saved data.
  • Limit values for each gauge can be set and displayed.
  • Settings for each gauge can be saved and managed under any name for each line.
  • Alarm output when a defect occurs. The number of defects is counted and displayed by type.
  • Distance correction for the defect marking unit allows defects to be marked accurately.
  • Outer diameter control units are also supported.

User Interface (PC Version)

User Interface

PC version of the RS485 system user interface: a development screen showing the settings of five gauges and graphs of their measured values

Monitors five gauges at the same time

The PC version of the user interface (*development screen). From the top, it monitors five gauges at once: laser outer diameter gauge (single-axis), laser outer diameter gauge (two-axis), laser outer diameter gauge (single-axis), eccentricity gauge, and capacitance monitor.
The preset and upper/lower limit values of each gauge can be read from the gauge or set on the PC. Measured values are visualized in the graph on the right.

User Interface (Touch Panel PC Version)

Touch Panel Interface

Touch panel PC version of the RS485 system user interface: a development screen showing the settings of five channels and graphs of their measured values

Change graphs and settings by touch

The touch panel PC (27-inch) version of the user interface (*development screen; OS: Windows 8.1).
The graph position and the parameter settings of each channel can be changed by touch.

System Overview

System Overview

RS485 System overview
RS485 System overview
ModelRS485 System
Communication methodMultipoint serial connection via RS485
Connected equipmentOur laser outer diameter gauges, irregularity detectors, capacitance monitors, joint detectors, and other equipment
Operation and managementSettings, commands, and data management on a panel PC
User interfacePC version, touch panel PC (27-inch) version
Data storageData from the start to the end of measurement saved in a CSV file
AvailabilityBuilt to Order

Documents for Evaluation

- Download

For case studies and products,
please feel free to contact us.

Have a question?
Our team is ready to help.

Contact

Tel. +81-42-645-8920

Hours: 9:00–17:30 JST, Monday–Friday (excluding Japanese public holidays)

General Inquiries