Where It Is Used
Use Cases

Wire and cable manufacturers
ProductionQuality controlProduction engineering

PVC and plastic pipe manufacturers
Production

Manufacturers with extrusion or drawing lines for rubber, glass tubing, tubing, and similar products
Quality assurance
Challenges We Solve
Solution
- Visual or sampling inspection misses lumps and dents, leading to complaints and recalls
- You want to inspect the full length of every product, even on high-speed lines (sampling misses defects)
- You want fewer false detections caused by wire twist, vibration, dirt, or dust
- You want the right detector for every wire diameter, from fine to extra-thick
- You want to locate defects so they can be repaired or removed (with marking integration)
Features of Takikawa Vision Outer Diameter Irregularity Detectors
Features
Our own design technology and more than 40 years of experience deliver high-precision measurement, long service life, and flexible customization.

Multi-axis monitoring (up to 16–20 axes) minimizes blind spots
Supports 1 to 16 detection directions and can be customized to 20 axes. Multi-axis monitoring catches lumps and dents on the surface.

Noise cancellation (TML) reduces false detection
The noise cancellation function of the high-end TML model reduces false detection caused by dirt, dust, and ambient light.

A wide lineup from φ0.02 to 130 mm for every line
Choose the right detector for each wire diameter, from fine to extra-thick.
Why Customers Choose Takikawa Vision
Why Us
Technology specialized in continuous measurement on extrusion lines, combined with the flexibility of a Japanese manufacturer. We support you from cost-effective adoption and customization through to after-sales support.
Continuous monitoring misses nothing, even on high-speed lines, unlike sampling methods
Continuous monitoring inspects the full length of every product, even on high-speed lines.
Multi-axis monitoring with up to 16–20 axes minimizes blind spots
A multi-axis configuration that also handles wire twist monitors the surface for lumps and dents.
Noise cancellation reduces false detection caused by dirt, dust, and ambient light
The noise cancellation function of the TML supports stable inspection.
Suitable for a Wide Range of Applications
Applications
Industries
PVC-insulated wire and communication cable
- 100% inspection for lumps and dents after extrusion coating
Power cable and extra-thick wire
- Surface monitoring for thick products (up to φ130 mm)
Glass tubing, plastic pipe, and rubber
- Appearance quality assurance on extrusion and molding lines
Position in the Process
Position in the Process
- Extrusion
- Outer diameter measurement (LDM/LOD)
- TM irregularity detection
- Take-up
Combined with the MAC (marking unit) and AL-03 (alarm unit), the system can also locate and remove defects.
Customization Examples
Custom Projects
We can customize our products for a wide range of cases.
Customization examples for this product are coming soon.
Specifications
Product Specification
Fine wire models (product diameter: Φ0.02–10 mm)
| Model | TM-503W | TM-1100XY | TM-1003W | TM-1104W | ||||
|---|---|---|---|---|---|---|---|---|
| CAD files | ||||||||
| Power supply unit | PW-02 | ― | PW-01/02 | ― | ||||
| CAD files | ― | ― | ||||||
| Detection directions | 3 directions | 2 directions | 3 directions | 4 directions | ||||
| Measurement method | Double-slit infrared LED projection | |||||||
| Applicable product diameter | φ0.02–3 mm | φ0.02–10 mm | φ0.02–8 mm | φ0.02–10 mm | ||||
| Irregularity detection range | 20–999 µm (setting level range) | |||||||
| Irregularity detection accuracy | Within ±1% of the maximum setting | |||||||
| Applicable line speed[*1] | 5–2000 m/min | 5–1500 m/min | ||||||
| Recorder output | ±0.2V/0.1mm | ±1V/0.1mm | ±0.5V/0.1mm | ±1V/0.1mm | ||||
| Alarm output | Red irregularity LED lights; relay contact output (250 V AC, 2 A, resistive load) | |||||||
| Alarm duration[*2] | 0.1 s | 0.5 s | 0.1 s | 0.5 s | ||||
| Power supply[*3] | DC±15V | AC100V 50/60Hz | DC±15V | AC100V 50/60Hz | ||||
| Power consumption | 6VA | 10VA | 6VA | 10VA | ||||
[*1] The line speed range depends on the height of the irregularity.
[*2] The alarm can be held with an option.
[*3] A 200 V AC power supply version is available as an option.
Medium wire models (product diameter: Φ0.1–35 mm)
| Model | TM-3001W | TM-3002W | TM-3004WA | TM-3008W (TM-3004WA) (TM-3004WB) | TM-3016W (TM-3004WA) (TM-3004WB) (TM-3004WC) (TM-3004WD) | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| CAD files | ||||||||||
| Detection directions | 1 direction | 2 directions | 4 directions | 8 directions | 16 directions | |||||
| Measurement method | Double-slit infrared LED projection | |||||||||
| Applicable product diameter | φ0.1–35 mm (up to φ45 mm depending on conditions) | |||||||||
| Irregularity detection range | 0.05–9.99 mm (setting level range) | |||||||||
| Irregularity detection accuracy | Within ±1% of the maximum setting | |||||||||
| Applicable line speed[*1] | 1–1500 m/min | |||||||||
| Recorder output | ±0.1 V/0.1 mm (each axis) | |||||||||
| Alarm output | Red irregularity LED lights; relay contact output (250 V AC, 2 A, resistive load) | |||||||||
| Alarm duration[*2] | 0.5 s | |||||||||
| Power supply[*3] | AC100V 50/60Hz | |||||||||
| Power consumption | 10VA | 10VA | 10VA | 20VA | 40VA | |||||
[*1] The line speed range depends on the height of the irregularity.
[*2] The alarm can be held with an option.
[*3] A 200 V AC power supply version is available as an option.
Thick wire models (product diameter: Φ0.1–60 mm)
| Model | TM-4001 | TM-4002 | TM-4004A | TM-4008 (TM-4004A) (TM-4004B) | TM-4016 (TM-4004A) (TM-4004B) (TM-4004C) (TM-4004D) | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| CAD files | ||||||||||
| Detection directions | 1 direction | 2 directions | 4 directions | 8 directions | 16 directions | |||||
| Measurement method | Single-slit white tungsten lamp projection | |||||||||
| Applicable product diameter | φ0.1–60 mm (up to φ65 mm depending on conditions) | |||||||||
| Irregularity detection range | 0.15–9.99 mm (setting level range) | |||||||||
| Irregularity detection accuracy | Within ±2% of the maximum setting | |||||||||
| Applicable line speed[*1] | 1–1500 m/min | 1–1000 m/min | ||||||||
| Recorder output | ±0.1 V/0.1 mm (each axis) | |||||||||
| Alarm output | LEDs light (dent: yellow / lump: red) Relay contact output (250 V AC, 2 A, resistive load; separate outputs for dents and lumps) | |||||||||
| Alarm duration[*2] | 0.5 s | |||||||||
| Power supply[*3] | AC100V 50/60Hz | |||||||||
| Power consumption | 10VA | 20VA | 30VA | 60VA | 120VA | |||||
[*1] The line speed range depends on the height of the irregularity.
[*2] The alarm can be held with an option.
[*3] A 200 V AC power supply version is available as an option.
Extra-thick wire models (product diameter: Φ1–130 mm)
| Model | TM-6004A | TM-6008 (TM-6004A) (TM-6004B) | TM-7003A | TM-7009 (TM-7003A) (TM-7003B) (TM-7003C) | ||||
|---|---|---|---|---|---|---|---|---|
| CAD files | ||||||||
| Detection directions | 4 directions | 8 directions | 3 directions | 9 directions | ||||
| Measurement method | Single-slit white tungsten lamp projection | |||||||
| Applicable product diameter | φ1–75 mm (up to φ90 mm depending on conditions) | φ1–100 mm (up to φ130 mm depending on conditions) | ||||||
| Irregularity detection range | 0.2–10 mm | |||||||
| Irregularity detection accuracy | Within ±2% of the maximum setting | |||||||
| Applicable line speed[*1] | 0.3–500 m/min | 0.5–100 m/min | ||||||
| Recorder output | ±0.1 V/0.1 mm (each axis) | |||||||
| Alarm output | LEDs light (dent: yellow / lump: red) Relay contact output (250 V AC, 2 A, resistive load; separate outputs for dents and lumps) | |||||||
| Alarm duration[*2] | 0.5 s | |||||||
| Power supply[*3] | AC100V 50/60Hz | |||||||
| Power consumption | 30VA | 60VA | 30VA | 90VA | ||||
[*1] The line speed range depends on the height of the irregularity.
[*2] The alarm can be held with an option.
[*3] A 200 V AC power supply version is available as an option.
Multi-axis models such as the 20-axis TM-6020 are also available.
Product Variations
Product Variations
Choose a configuration for your wire diameter, detection directions, and line conditions from a wide lineup covering φ0.02 to 130 mm. Please contact us for the applicable wire diameters and detection conditions of each model.
Variations by Size

Fine wire series
Applications and features: For φ0.02–5 mm

Medium wire series
Applications and features: For φ0.1–35 mm

Thick wire series
Applications and features: For φ0.1–60 mm

Extra-thick wire series
Applications and features: For φ1–130 mm
Specification Table
| Detection directions | Up to 16 directions (varies by model) |
|---|---|
| Measurement method | Slit projection |
| Light source | LED or tungsten lamp (varies by model) |
| Irregularity detection range | 20 μm–10 mm (varies by model) |
| Detection accuracy | Within ±1% to 2% of the maximum setting (varies by model) |
| Applicable line speed | 0.3–2000 m/min (varies by model) |
| External output | Analog |
| Power supply | ±15 V DC or 100 V AC, 50/60 Hz (varies by model) |
| Operating environment | −5°C to 50°C (non-condensing) |
FAQ
FAQ
How small a lump or dent can it detect?
It can detect irregularities as small as 10 μm (depending on the model and conditions).
Does it falsely detect dirt or dust?
The TML with noise cancellation reduces false detection caused by dirt and dust.
How do wire twist and vibration affect it?
The double-slit method and multi-axis configuration reduce their effect.
Can it be used on high-speed lines?
Yes, at up to 2,000 m/min.
Can it locate the position of defects?
Yes, in combination with the MAC (marking unit).
Can we run a detection test with samples before purchase?
Yes, we can run detection tests with your samples. Please contact us when you are considering a purchase.
Documents for Evaluation
- Download
For case studies and products,
please feel free to contact us.