Overview
In transparent tubing, light passes through only partially and the signal is unstable. Installing the detector at an angle allows burn marks and foreign matter inside to be detected reliably.
The Challenge
Burnt residue formed during extrusion can stick to the inside of the tubing. Transparent tubing lets light through only partially, so the signal was unstable and detection was difficult.
Our Solution
Installing the detector at an angle to change the light path reduced signal variation, so foreign matter inside could be detected reliably.
Key Point
An example solved by how the equipment was installed rather than by changing it. We find the best way to use our equipment by testing together with you on site.